#HP MSA 2040 Setup Guide ##Scratch profile
- Navigate to the URL of the controller array
- Enter the default username and password
- Using the top navigation bar, click
System: <hostname> -> Set System Information
| Field | Information required |
|---|---|
| System Name | Hostname, e.g. hablkary1-1
|
| System Contact | Alces Software |
| System Location | Rack name e.g. rackA1
|
| System Information | hpccluster - scratch storage |
- Navigate to
System -> Rear- note down all chassis and controller serial numbers - Navigate to
PoolsAction -> Add Disk Group
Per disk array, create 1 disk group with the following settings:
| Option | Setting |
|---|---|
Type |
Linear |
Name |
<scratch/tierX>-ostX |
RAID Level |
RAID-6 |
Chunk size |
128KB |
Online Initialisation |
Yes |
Add disks 1-10 into the RAID6 pool, and optionally select the hot-spare disk into the SPARE pool.
Repeat for each disk array in the group.
- Navigate to
VolumesAction -> Create Linear Volumes
For each disk pool, create a linear volume with the following settings:
| Option | Setting |
|---|---|
Pool |
Disk pool, e.g. tier1-ost1
|
Number of volumes |
1 |
Volume name |
Default provided, e.g. tier1-ost1_v0001
|
Volume size |
Default provided |
Enable snapshots |
Disabled |
Repeat for each disk pool created