#HP MSA 2040 Setup Guide ##Scratch profile

  • Navigate to the URL of the controller array
  • Enter the default username and password
  • Using the top navigation bar, click System: <hostname> -> Set System Information
Field Information required
System Name Hostname, e.g. hablkary1-1
System Contact Alces Software
System Location Rack name e.g. rackA1
System Information hpccluster - scratch storage
  • Navigate to System -> Rear - note down all chassis and controller serial numbers
  • Navigate to Pools
    • Action -> Add Disk Group

Per disk array, create 1 disk group with the following settings:

Option Setting
Type Linear
Name <scratch/tierX>-ostX
RAID Level RAID-6
Chunk size 128KB
Online Initialisation Yes

Add disks 1-10 into the RAID6 pool, and optionally select the hot-spare disk into the SPARE pool. Repeat for each disk array in the group.

  • Navigate to Volumes
    • Action -> Create Linear Volumes

For each disk pool, create a linear volume with the following settings:

Option Setting
Pool Disk pool, e.g. tier1-ost1
Number of volumes 1
Volume name Default provided, e.g. tier1-ost1_v0001
Volume size Default provided
Enable snapshots Disabled

Repeat for each disk pool created