-
Notifications
You must be signed in to change notification settings - Fork 2
Expand file tree
/
Copy pathcircle.py
More file actions
1369 lines (1212 loc) · 51 KB
/
circle.py
File metadata and controls
1369 lines (1212 loc) · 51 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
"""Plugwise Circle node class."""
from __future__ import annotations
from asyncio import Task, create_task
from collections.abc import Awaitable, Callable
from dataclasses import replace
from datetime import UTC, datetime, timedelta
from functools import wraps
import logging
from typing import Any, Final, TypeVar, cast
from ..api import (
EnergyStatistics,
NodeEvent,
NodeFeature,
NodeInfo,
NodeInfoMessage,
NodeType,
PowerStatistics,
RelayConfig,
RelayLock,
RelayState,
)
from ..connection import StickController
from ..constants import (
DAY_IN_HOURS,
DEFAULT_CONS_INTERVAL,
MAX_TIME_DRIFT,
MINIMAL_POWER_UPDATE,
NO_PRODUCTION_INTERVAL,
PULSES_PER_KW_SECOND,
SECOND_IN_NANOSECONDS,
)
from ..exceptions import FeatureError, MessageError, NodeError
from ..messages.requests import (
CircleClockGetRequest,
CircleClockSetRequest,
CircleEnergyLogsRequest,
CircleMeasureIntervalRequest,
CirclePowerUsageRequest,
CircleRelayInitStateRequest,
CircleRelaySwitchRequest,
EnergyCalibrationRequest,
NodeInfoRequest,
)
from ..messages.responses import NodeInfoResponse, NodeResponseType
from .helpers import EnergyCalibration, raise_not_loaded
from .helpers.counter import EnergyCounters
from .helpers.firmware import CIRCLE_FIRMWARE_SUPPORT
from .helpers.pulses import PulseLogRecord, calc_log_address
from .node import PlugwiseBaseNode
CACHE_CALIBRATION_GAIN_A = "calibration_gain_a"
CACHE_CALIBRATION_GAIN_B = "calibration_gain_b"
CACHE_CALIBRATION_NOISE = "calibration_noise"
CACHE_CALIBRATION_TOT = "calibration_tot"
CACHE_ENERGY_COLLECTION = "energy_collection"
CACHE_RELAY = "relay"
CACHE_RELAY_INIT = "relay_init"
CACHE_RELAY_LOCK = "relay_lock"
CIRCLE_FEATURES: Final = (
NodeFeature.CIRCLE,
NodeFeature.RELAY,
NodeFeature.RELAY_INIT,
NodeFeature.RELAY_LOCK,
NodeFeature.ENERGY,
NodeFeature.POWER,
)
# Default firmware if not known
DEFAULT_FIRMWARE: Final = datetime(2008, 8, 26, 15, 46, tzinfo=UTC)
FuncT = TypeVar("FuncT", bound=Callable[..., Any])
_LOGGER = logging.getLogger(__name__)
def raise_calibration_missing(func: FuncT) -> FuncT:
"""Validate energy calibration settings are available."""
@wraps(func)
def decorated(*args: Any, **kwargs: Any) -> Any:
if args[0].calibrated is None:
raise NodeError("Energy calibration settings are missing")
return func(*args, **kwargs)
return cast(FuncT, decorated)
class PlugwiseCircle(PlugwiseBaseNode):
"""Plugwise Circle node."""
def __init__(
self,
mac: str,
node_type: NodeType,
controller: StickController,
loaded_callback: Callable[[NodeEvent, str], Awaitable[None]],
):
"""Initialize base class for Sleeping End Device."""
super().__init__(mac, node_type, controller, loaded_callback)
# Relay
self._relay_lock: RelayLock = RelayLock()
self._relay_state: RelayState = RelayState()
self._relay_config: RelayConfig = RelayConfig()
# Power
self._power: PowerStatistics = PowerStatistics()
self._calibration: EnergyCalibration | None = None
# Energy
self._energy_counters = EnergyCounters(mac)
self._retrieve_energy_logs_task: None | Task[None] = None
self._last_energy_log_requested: bool = False
self._last_collected_energy_timestamp: datetime | None = None
self._group_member: list[int] = []
# region Properties
@property
def calibrated(self) -> bool:
"""State of calibration."""
if self._calibration is not None:
return True
return False
@property
def energy(self) -> EnergyStatistics:
"""Energy statistics."""
return self._energy_counters.energy_statistics
@property
@raise_not_loaded
def energy_consumption_interval(self) -> int | None:
"""Interval (minutes) energy consumption counters are locally logged at Circle devices."""
if NodeFeature.ENERGY not in self._features:
raise NodeError(f"Energy log interval is not supported for node {self.mac}")
return self._energy_counters.consumption_interval
@property
def energy_production_interval(self) -> int | None:
"""Interval (minutes) energy production counters are locally logged at Circle devices."""
if NodeFeature.ENERGY not in self._features:
raise NodeError(f"Energy log interval is not supported for node {self.mac}")
return self._energy_counters.production_interval
@property
@raise_not_loaded
def power(self) -> PowerStatistics:
"""Power statistics."""
return self._power
@property
@raise_not_loaded
def relay(self) -> bool:
"""Current value of relay."""
return bool(self._relay_state.state)
@property
@raise_not_loaded
def relay_config(self) -> RelayConfig:
"""Configuration state of relay."""
if NodeFeature.RELAY_INIT not in self._features:
raise FeatureError(
f"Configuration of relay is not supported for device {self.name}"
)
return self._relay_config
@property
@raise_not_loaded
def relay_state(self) -> RelayState:
"""State of relay."""
return self._relay_state
@raise_not_loaded
async def relay_off(self) -> None:
"""Switch relay off."""
await self.set_relay(False)
@raise_not_loaded
async def relay_on(self) -> None:
"""Switch relay on."""
await self.set_relay(True)
@raise_not_loaded
async def relay_init_off(self) -> None:
"""Switch relay off."""
await self._relay_init_set(False)
@raise_not_loaded
async def relay_init_on(self) -> None:
"""Switch relay on."""
await self._relay_init_set(True)
@property
def relay_lock(self) -> RelayLock:
"""State of the relay lock."""
return self._relay_lock
# endregion
async def calibration_update(self) -> bool:
"""Retrieve and update calibration settings. Returns True if successful."""
_LOGGER.debug(
"Start updating energy calibration for %s",
self._mac_in_str,
)
request = EnergyCalibrationRequest(self._send, self._mac_in_bytes)
if (calibration_response := await request.send()) is None:
_LOGGER.warning(
"Retrieving energy calibration information for %s failed",
self.name,
)
await self._available_update_state(False)
return False
await self._available_update_state(True, calibration_response.timestamp)
await self._calibration_update_state(
calibration_response.gain_a,
calibration_response.gain_b,
calibration_response.off_noise,
calibration_response.off_tot,
)
_LOGGER.debug(
"Updating energy calibration for %s succeeded",
self._mac_in_str,
)
return True
async def _calibration_load_from_cache(self) -> bool:
"""Load calibration settings from cache."""
cal_gain_a: float | None = None
cal_gain_b: float | None = None
cal_noise: float | None = None
cal_tot: float | None = None
if (gain_a := self._get_cache(CACHE_CALIBRATION_GAIN_A)) is not None:
cal_gain_a = float(gain_a)
if (gain_b := self._get_cache(CACHE_CALIBRATION_GAIN_B)) is not None:
cal_gain_b = float(gain_b)
if (noise := self._get_cache(CACHE_CALIBRATION_NOISE)) is not None:
cal_noise = float(noise)
if (tot := self._get_cache(CACHE_CALIBRATION_TOT)) is not None:
cal_tot = float(tot)
# Restore calibration
result = await self._calibration_update_state(
cal_gain_a,
cal_gain_b,
cal_noise,
cal_tot,
load_from_cache=True,
)
if result:
_LOGGER.debug(
"Restore calibration settings from cache for %s was successful",
self._mac_in_str,
)
return True
_LOGGER.info(
"Failed to restore calibration settings from cache for %s", self.name
)
return False
async def _calibration_update_state(
self,
gain_a: float | None,
gain_b: float | None,
off_noise: float | None,
off_tot: float | None,
load_from_cache: bool = False,
) -> bool:
"""Process new energy calibration settings. Returns True if successful."""
if gain_a is None or gain_b is None or off_noise is None or off_tot is None:
return False
self._calibration = EnergyCalibration(
gain_a=gain_a, gain_b=gain_b, off_noise=off_noise, off_tot=off_tot
)
# Forward calibration config to energy collection
self._energy_counters.calibration = self._calibration
if self._cache_enabled and not load_from_cache:
self._set_cache(CACHE_CALIBRATION_GAIN_A, gain_a)
self._set_cache(CACHE_CALIBRATION_GAIN_B, gain_b)
self._set_cache(CACHE_CALIBRATION_NOISE, off_noise)
self._set_cache(CACHE_CALIBRATION_TOT, off_tot)
await self.save_cache()
return True
@raise_calibration_missing
async def power_update(self) -> PowerStatistics | None:
"""Update the current power usage statistics.
Return power usage or None if retrieval failed
"""
# Debounce power
if self.skip_update(self._power, MINIMAL_POWER_UPDATE):
return self._power
request = CirclePowerUsageRequest(self._send, self._mac_in_bytes)
response = await request.send()
if response is None or response.timestamp is None:
_LOGGER.debug(
"No response for async_power_update() for %s", self._mac_in_str
)
await self._available_update_state(False)
return None
await self._available_update_state(True, response.timestamp)
# Update power stats
self._power.last_second = self._calc_watts(
response.pulse_1s, 1, response.offset
)
self._power.last_8_seconds = self._calc_watts(
response.pulse_8s, 8, response.offset
)
self._power.timestamp = response.timestamp
await self.publish_feature_update_to_subscribers(NodeFeature.POWER, self._power)
# Forward pulse interval counters to pulse Collection
self._energy_counters.add_pulse_stats(
response.consumed_counter,
response.produced_counter,
response.timestamp,
)
await self.publish_feature_update_to_subscribers(
NodeFeature.ENERGY, self._energy_counters.energy_statistics
)
return self._power
def _log_no_energy_stats_update(self) -> None:
"""Return log-message based on conditions."""
if (
self._initialization_delay_expired is not None
and datetime.now(tz=UTC) < self._initialization_delay_expired
):
_LOGGER.info(
"Unable to return energy statistics for %s during initialization, because it is not responding",
self.name,
)
else:
_LOGGER.warning(
"Unable to return energy statistics for %s, because it is not responding",
self.name,
)
@raise_not_loaded
@raise_calibration_missing
async def energy_update(self) -> EnergyStatistics | None: # noqa: PLR0911 PLR0912
"""Return updated energy usage statistics."""
if self._current_log_address is None:
_LOGGER.debug(
"Unable to update energy logs for node %s because the current log address is unknown.",
self._mac_in_str,
)
if await self.node_info_update() is None:
self._log_no_energy_stats_update()
return None
# Request node info update every 30 minutes.
elif not self.skip_update(self._node_info, 1800):
if await self.node_info_update() is None:
self._log_no_energy_stats_update()
return None
# Always request last energy log records at initial startup
if not self._last_energy_log_requested:
self._last_energy_log_requested = await self.energy_log_update(
self._current_log_address
)
if self._energy_counters.log_rollover:
# Try updating node_info to collect the updated energy log address
if await self.node_info_update() is None:
_LOGGER.debug(
"async_energy_update | %s | Log rollover | node_info_update failed",
self._mac_in_str,
)
return None
# Try collecting energy-stats for _current_log_address
result = await self.energy_log_update(self._current_log_address)
if not result:
_LOGGER.debug(
"async_energy_update | %s | Log rollover | energy_log_update failed",
self._mac_in_str,
)
return None
if self._current_log_address is not None:
# Retry with previous log address as Circle node pointer to self._current_log_address
# could be rolled over while the last log is at previous address/slot
_prev_log_address, _ = calc_log_address(
self._current_log_address, 1, -4
)
result = await self.energy_log_update(_prev_log_address)
if not result:
_LOGGER.debug(
"async_energy_update | %s | Log rollover | energy_log_update %s failed",
self._mac_in_str,
_prev_log_address,
)
return None
if (
missing_addresses := self._energy_counters.log_addresses_missing
) is not None:
if len(missing_addresses) == 0:
await self.power_update()
_LOGGER.debug(
"async_energy_update for %s | no missing log records",
self._mac_in_str,
)
return self._energy_counters.energy_statistics
if len(missing_addresses) == 1:
result = await self.energy_log_update(missing_addresses[0])
if result:
await self.power_update()
_LOGGER.debug(
"async_energy_update for %s | single energy log is missing | %s",
self._mac_in_str,
missing_addresses,
)
return self._energy_counters.energy_statistics
# Create task to request remaining missing logs
if (
self._retrieve_energy_logs_task is None
or self._retrieve_energy_logs_task.done()
):
_LOGGER.debug(
"Create task to update energy logs for node %s",
self._mac_in_str,
)
self._retrieve_energy_logs_task = create_task(
self.get_missing_energy_logs()
)
if (
self._initialization_delay_expired is not None
and datetime.now(tz=UTC) < self._initialization_delay_expired
):
_LOGGER.info(
"Unable to return energy statistics for %s during initialization, collecting required data...",
self.name,
)
else:
_LOGGER.warning(
"Unable to return energy statistics for %s, collecting required data...",
self.name,
)
return None
async def _get_initial_energy_logs(self) -> None:
"""Collect initial energy logs from the last 10 log addresses."""
if self._current_log_address is None:
return
_LOGGER.debug(
"Start collecting initial energy logs from the last 10 log addresses for node %s.",
self._mac_in_str,
)
total_addresses = 11
log_address = self._current_log_address
while total_addresses > 0:
result = await self.energy_log_update(log_address)
if not result:
# Handle case with None-data in all address slots
_LOGGER.debug(
"All slots at log address %s are empty or outdated – stopping initial collection",
log_address,
)
break
log_address, _ = calc_log_address(log_address, 1, -4)
total_addresses -= 1
if self._cache_enabled:
await self._energy_log_records_save_to_cache()
async def get_missing_energy_logs(self) -> None:
"""Task to retrieve missing energy logs."""
self._energy_counters.update()
if self._current_log_address is None:
return
if (missing_addresses := self._energy_counters.log_addresses_missing) is None:
await self._get_initial_energy_logs()
return
_LOGGER.debug("Task created to get missing logs of %s", self._mac_in_str)
_LOGGER.debug(
"Task Request %s missing energy logs for node %s | %s",
str(len(missing_addresses)),
self._mac_in_str,
str(missing_addresses),
)
missing_addresses = sorted(missing_addresses, reverse=True)
tasks = [
create_task(self.energy_log_update(address))
for address in missing_addresses
]
for task in tasks:
await task
if self._cache_enabled:
await self._energy_log_records_save_to_cache()
async def energy_log_update(self, address: int | None) -> bool:
"""Request energy logs and return True only when at least one recent, non-empty record was stored; otherwise return False."""
any_record_stored = False
if address is None:
return False
_LOGGER.debug(
"Requesting EnergyLogs from node %s address %s",
self._mac_in_str,
address,
)
request = CircleEnergyLogsRequest(self._send, self._mac_in_bytes, address)
if (response := await request.send()) is None:
_LOGGER.debug(
"Retrieving EnergyLogs data from node %s failed",
self._mac_in_str,
)
return False
_LOGGER.debug("EnergyLogs from node %s, address=%s:", self._mac_in_str, address)
await self._available_update_state(True, response.timestamp)
# Forward historical energy log information to energy counters
# Each response message contains 4 log counters (slots) of the
# energy pulses collected during the previous hour of given timestamp
last_energy_timestamp_collected = False
for _slot in range(4, 0, -1):
log_timestamp, log_pulses = response.log_data[_slot]
_LOGGER.debug(
"In slot=%s: pulses=%s, timestamp=%s", _slot, log_pulses, log_timestamp
)
if (
log_timestamp is None
or log_pulses is None
# Don't store an old log-record, store am empty record instead
or not self._check_timestamp_is_recent(address, _slot, log_timestamp)
):
self._energy_counters.add_empty_log(response.log_address, _slot)
continue
if await self._energy_log_record_update_state(
response.log_address,
_slot,
log_timestamp.replace(tzinfo=UTC),
log_pulses,
import_only=True,
):
any_record_stored = True
if not last_energy_timestamp_collected:
# Collect the timestamp of the most recent response
self._last_collected_energy_timestamp = log_timestamp.replace(
tzinfo=UTC
)
_LOGGER.debug(
"Setting last_collected_energy_timestamp to %s",
self._last_collected_energy_timestamp,
)
last_energy_timestamp_collected = True
self._energy_counters.update()
if any_record_stored:
_LOGGER.debug(
"Saving energy record update to cache for %s", self._mac_in_str
)
await self.save_cache()
return any_record_stored
def _check_timestamp_is_recent(
self, address: int, slot: int, timestamp: datetime
) -> bool:
"""Check if the timestamp of the received log-record is recent.
A timestamp from within the last 24 hours is considered recent.
"""
age_seconds = (
datetime.now(tz=UTC) - timestamp.replace(tzinfo=UTC)
).total_seconds()
if age_seconds > DAY_IN_HOURS * 3600:
_LOGGER.warning(
"EnergyLog from Node %s | address %s | slot %s | timestamp %s is outdated, ignoring...",
self._mac_in_str,
address,
slot,
timestamp,
)
return False
return True
async def _energy_log_records_load_from_cache(self) -> bool: # noqa: PLR0912
"""Load energy_log_record from cache."""
if (cache_data := self._get_cache(CACHE_ENERGY_COLLECTION)) is None:
_LOGGER.warning(
"Failed to restore energy log records from cache for node %s", self.name
)
return False
restored_logs: dict[int, dict[int, tuple[datetime, int]]] = {}
if cache_data == "":
_LOGGER.debug("Cache-record is empty")
return False
log_data = cache_data.split("|")
for log_record in log_data:
log_fields = log_record.split(":")
if len(log_fields) == 4:
timestamp_energy_log = log_fields[2].split("-")
if len(timestamp_energy_log) == 6:
address = int(log_fields[0])
slot = int(log_fields[1])
pulses = int(log_fields[3])
timestamp = datetime(
year=int(timestamp_energy_log[0]),
month=int(timestamp_energy_log[1]),
day=int(timestamp_energy_log[2]),
hour=int(timestamp_energy_log[3]),
minute=int(timestamp_energy_log[4]),
second=int(timestamp_energy_log[5]),
tzinfo=UTC,
)
if restored_logs.get(address) is None:
restored_logs[address] = {}
restored_logs[address][slot] = (timestamp, pulses)
# Sort and prune the records loaded from cache
sorted_logs: dict[int, dict[int, tuple[datetime, int]]] = {}
skip_before = datetime.now(tz=UTC) - timedelta(hours=DAY_IN_HOURS)
sorted_addresses = sorted(restored_logs.keys(), reverse=True)
for address in sorted_addresses:
sorted_slots = sorted(restored_logs[address].keys(), reverse=True)
for slot in sorted_slots:
if restored_logs[address][slot][0] > skip_before:
if sorted_logs.get(address) is None:
sorted_logs[address] = {}
sorted_logs[address][slot] = restored_logs[address][slot]
for address, data in sorted_logs.items():
for slot, pulse_data in data.items():
self._energy_counters.add_pulse_log(
address=address,
slot=slot,
pulses=pulse_data[1],
timestamp=pulse_data[0],
import_only=True,
)
self._energy_counters.update()
# Create task to retrieve remaining (missing) logs
if self._energy_counters.log_addresses_missing is None:
_LOGGER.debug("Cache | missing log addresses is None")
return False
if len(self._energy_counters.log_addresses_missing) > 0:
if self._retrieve_energy_logs_task is not None:
if not self._retrieve_energy_logs_task.done():
await self._retrieve_energy_logs_task
self._retrieve_energy_logs_task = create_task(
self.get_missing_energy_logs()
)
_LOGGER.debug("Cache | creating tasks to obtain missing energy logs")
return False
return True
async def _energy_log_records_save_to_cache(self) -> None:
"""Save currently collected energy logs to cached file."""
if not self._cache_enabled:
return
logs: dict[int, dict[int, PulseLogRecord]] = (
self._energy_counters.get_pulse_logs()
)
cached_logs = ""
# logs is already sorted in reverse
for address, record in logs.items():
for slot in record:
log = record[slot]
if cached_logs != "":
cached_logs += "|"
cached_logs += f"{address}:{slot}:{log.timestamp.year}"
cached_logs += f"-{log.timestamp.month}-{log.timestamp.day}"
cached_logs += f"-{log.timestamp.hour}-{log.timestamp.minute}"
cached_logs += f"-{log.timestamp.second}:{log.pulses}"
_LOGGER.debug("Saving energy logrecords to cache for %s", self._mac_in_str)
self._set_cache(CACHE_ENERGY_COLLECTION, cached_logs)
async def _energy_log_record_update_state(
self,
address: int,
slot: int,
timestamp: datetime,
pulses: int,
import_only: bool = False,
) -> bool:
"""Process new energy log record. Returns true if record is new or changed."""
self._energy_counters.add_pulse_log(
address, slot, timestamp, pulses, import_only=import_only
)
if not self._cache_enabled:
return False
log_cache_record = f"{address}:{slot}:{timestamp.year}"
log_cache_record += f"-{timestamp.month}-{timestamp.day}"
log_cache_record += f"-{timestamp.hour}-{timestamp.minute}"
log_cache_record += f"-{timestamp.second}:{pulses}"
if (cached_logs := self._get_cache(CACHE_ENERGY_COLLECTION)) is not None:
if log_cache_record not in cached_logs:
_LOGGER.debug(
"Adding logrecord (%s, %s) to cache of %s",
str(address),
str(slot),
self._mac_in_str,
)
self._set_cache(
CACHE_ENERGY_COLLECTION, log_cache_record + "|" + cached_logs
)
return True
_LOGGER.debug(
"Energy logrecord already present for %s, ignoring", self._mac_in_str
)
return False
_LOGGER.debug(
"Cache is empty, adding new logrecord (%s, %s) for %s",
str(address),
str(slot),
self._mac_in_str,
)
self._set_cache(CACHE_ENERGY_COLLECTION, log_cache_record)
return True
@raise_not_loaded
async def set_relay(self, state: bool) -> bool:
"""Change the state of the relay."""
if NodeFeature.RELAY not in self._features:
raise FeatureError(
f"Changing state of relay is not supported for node {self.mac}"
)
if self._relay_lock.state:
_LOGGER.debug("Relay switch blocked, relay is locked")
return self._relay_state.state
_LOGGER.debug("Switching relay to %s", state)
request = CircleRelaySwitchRequest(self._send, self._mac_in_bytes, state)
response = await request.send()
if response is None or response.ack_id == NodeResponseType.RELAY_SWITCH_FAILED:
raise NodeError(f"Request to switch relay for {self.name} failed")
if response.ack_id == NodeResponseType.RELAY_SWITCHED_OFF:
await self._relay_update_state(state=False, timestamp=response.timestamp)
return False
if response.ack_id == NodeResponseType.RELAY_SWITCHED_ON:
await self._relay_update_state(state=True, timestamp=response.timestamp)
return True
raise NodeError(
f"Unexpected NodeResponseType {response.ack_id!r} received "
+ "in response to CircleRelaySwitchRequest for node {self.mac}"
)
@raise_not_loaded
async def set_relay_lock(self, state: bool) -> bool:
"""Set the state of the relay-lock."""
await self._relay_update_lock(state)
return state
async def _relay_load_from_cache(self) -> bool:
"""Load relay state from cache."""
result = True
if (cached_relay_data := self._get_cache(CACHE_RELAY)) is not None:
_LOGGER.debug(
"Restore relay state from cache for node %s: relay: %s",
self._mac_in_str,
cached_relay_data,
)
relay_state = cached_relay_data == "True"
await self._relay_update_state(relay_state)
else:
_LOGGER.debug(
"Failed to restore relay state from cache for node %s, try to request node info...",
self._mac_in_str,
)
if await self.node_info_update() is None:
result = False
if (cached_relay_lock := self._get_cache(CACHE_RELAY_LOCK)) is not None:
_LOGGER.debug(
"Restore relay_lock state from cache for node %s: relay_lock: %s",
self._mac_in_str,
cached_relay_lock,
)
relay_lock = cached_relay_lock == "True"
await self._relay_update_lock(relay_lock, load_from_cache=True)
else:
# Set to initial state False when not present in cache
await self._relay_update_lock(False)
return result
async def _relay_update_state(
self, state: bool, timestamp: datetime | None = None
) -> None:
"""Process relay state update."""
state_update = False
if state:
self._set_cache(CACHE_RELAY, "True")
if self._relay_state.state is None or not self._relay_state.state:
state_update = True
else:
self._set_cache(CACHE_RELAY, "False")
if self._relay_state.state is None or self._relay_state.state:
state_update = True
self._relay_state = replace(self._relay_state, state=state, timestamp=timestamp)
if state_update:
await self.publish_feature_update_to_subscribers(
NodeFeature.RELAY, self._relay_state
)
_LOGGER.debug("Saving relay state update to cache for %s", self._mac_in_str)
await self.save_cache()
async def _relay_update_lock(
self, state: bool, load_from_cache: bool = False
) -> None:
"""Process relay lock update."""
state_update = False
if state:
self._set_cache(CACHE_RELAY_LOCK, "True")
if self._relay_lock.state is None or not self._relay_lock.state:
state_update = True
else:
self._set_cache(CACHE_RELAY_LOCK, "False")
if self._relay_lock.state is None or self._relay_lock.state:
state_update = True
if state_update:
self._relay_lock = replace(self._relay_lock, state=state)
await self.publish_feature_update_to_subscribers(
NodeFeature.RELAY_LOCK, self._relay_lock
)
if not load_from_cache:
_LOGGER.debug(
"Saving relay lock state update to cache for %s", self._mac_in_str
)
await self.save_cache()
async def clock_synchronize(self) -> bool:
"""Synchronize clock. Returns true if successful."""
get_clock_request = CircleClockGetRequest(self._send, self._mac_in_bytes)
clock_response = await get_clock_request.send()
if clock_response is None or clock_response.timestamp is None:
return False
_dt_of_circle = datetime.now(tz=UTC).replace(
hour=clock_response.time.hour.value,
minute=clock_response.time.minute.value,
second=clock_response.time.second.value,
microsecond=0,
tzinfo=UTC,
)
clock_offset = clock_response.timestamp.replace(microsecond=0) - _dt_of_circle
if (clock_offset.seconds < MAX_TIME_DRIFT) or (
clock_offset.seconds > -(MAX_TIME_DRIFT)
):
return True
_LOGGER.info(
"Reset clock of node %s because time has drifted %s sec",
self._mac_in_str,
str(clock_offset.seconds),
)
if self._node_protocols is None:
raise NodeError(
"Unable to synchronize clock en when protocol version is unknown"
)
set_clock_request = CircleClockSetRequest(
self._send,
self._mac_in_bytes,
datetime.now(tz=UTC),
self._node_protocols.max,
)
if (node_response := await set_clock_request.send()) is None:
_LOGGER.warning(
"Failed to (re)set the internal clock of %s",
self.name,
)
return False
if node_response.ack_id == NodeResponseType.CLOCK_ACCEPTED:
return True
return False
async def load(self) -> None:
"""Load and activate Circle node features."""
if self._loaded:
return
if self._cache_enabled:
_LOGGER.debug("Loading Circle node %s from cache", self._mac_in_str)
if await self._load_from_cache():
self._loaded = True
if not self._loaded:
_LOGGER.debug("Retrieving Info For Circle node %s", self._mac_in_str)
# Check if node is online
if (
not self._available
and not await self.is_online()
or await self.node_info_update() is None
):
_LOGGER.debug(
"Failed to retrieve NodeInfo for %s, loading defaults",
self._mac_in_str,
)
await self._load_defaults()
self._loaded = True
self._setup_protocol(CIRCLE_FIRMWARE_SUPPORT, CIRCLE_FEATURES)
await self._loaded_callback(NodeEvent.LOADED, self.mac)
await self.initialize()
async def _load_from_cache(self) -> bool:
"""Load states from previous cached information. Returns True if successful."""
result = True
if not await super()._load_from_cache():
_LOGGER.debug("_load_from_cache | super-load failed")
result = False
# Calibration settings
if not await self._calibration_load_from_cache():
_LOGGER.debug(
"Node %s failed to load calibration from cache", self._mac_in_str
)
if result:
result = False
# Energy collection
if not await self._energy_log_records_load_from_cache():
_LOGGER.warning(
"Node %s failed to load energy_log_records from cache",
self._mac_in_str,
)
if result:
result = False
# Relay
if not await self._relay_load_from_cache():
_LOGGER.debug(
"Node %s failed to load relay state from cache",
self._mac_in_str,
)
if result:
result = False
# Relay init config if feature is enabled
if NodeFeature.RELAY_INIT in self._features:
if not await self._relay_init_load_from_cache():
_LOGGER.debug(
"Node %s failed to load relay_init state from cache",
self._mac_in_str,
)
if result:
result = False
return result
async def _load_defaults(self) -> None:
"""Load default configuration settings."""
if self._node_info.model is None:
self._node_info.model = "Circle"
if self._node_info.name is None:
self._node_info.name = f"Circle {self._node_info.mac[-5:]}"
if self._node_info.firmware is None:
self._node_info.firmware = DEFAULT_FIRMWARE
@raise_not_loaded
async def initialize(self) -> bool:
"""Initialize node."""
if self._initialized:
_LOGGER.debug("Already initialized node %s", self._mac_in_str)
return True
if not await self.clock_synchronize():
_LOGGER.debug(
"Failed to initialized node %s, failed clock sync", self._mac_in_str
)
self._initialized = False
return False