Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathconnection_table.py
More file actions
117 lines (101 loc) · 5.18 KB
/
connection_table.py
File metadata and controls
117 lines (101 loc) · 5.18 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
from labscript import *
from labscript import AnalogOut
from labscript_devices.DummyPseudoclock.labscript_devices import DummyPseudoclock
from labscript_devices.DummyIntermediateDevice import DummyIntermediateDevice
from labscript_devices.NI_DAQmx.models.NI_PXIe_6738 import NI_PXIe_6738
from labscript_devices.NI_DAQmx.models.NI_PXIe_6363 import NI_PXIe_6363
from labscript_devices.IMAQdxCamera.labscript_devices import IMAQdxCamera
from labscript_devices.PrawnBlaster.labscript_devices import PrawnBlaster
#from labscript_devices import IDS_PeakCamera
from user_devices.IDS_PeakCamera.labscript_devices import IDS_PeakCamera
from user_devices.BBD301.labscript_devices import BBD301
def ct():
PrawnBlaster(
name = 'prawn',
com_port = 'COM11',
num_pseudoclocks = 1,
pico_board = 'pico2'
)
SLOT_6738 = "PXI1Slot3" # EXACT name from NI-MAX
SLOT_6363 = "PXI1Slot2" # EXACT name from NI-MAX
NI_PXIe_6738(
name = 'NI6738',
parent_device = prawn.clocklines[0],
MAX_name = SLOT_6738,
clock_terminal = '/PXI1Slot3/PFI0', # <-- empty string means "use internal/Onboard clock"
max_AO_sample_rate = 100000.00000000001,
)
NI_PXIe_6363(
name = 'NI6363',
parent_device = prawn.clocklines[0],
MAX_name=SLOT_6363,
clock_terminal = '/PXI1Slot2/PFI12', # <-- empty string means "use internal/Onboard clock"
acquisition_rate=100e3
)
# Define digital outs on 6363
#make sure to define an even number of channels for Labscript to be happy
Shutter(name='REPUMP_SHUTTER_do', parent_device=NI6363, connection='port0/line0',
delay=(5.94e-3, 5.6e-3), open_state=1) #Delays coppied from MRR, not directly tested!
DigitalOut(name='MAIN_REL_JUMP_do', parent_device=NI6363, connection='port0/line1')
DigitalOut(name='LCR_BOT_do', parent_device=NI6363, connection='port0/line2')
DigitalOut(name='MOT_COIL_do', parent_device=NI6363, connection='port0/line3')
DigitalOut(name='MRR_TRIG_do', parent_device=NI6363, connection='port0/line4')
Shutter(name='MOT_SHUTTER_do', parent_device=NI6363, connection='port0/line5',
delay=(6e-3, 6e-3), open_state=1) #delays are a guess.
Shutter(name='MRR_SHUTTER_do', parent_device=NI6363, connection='port0/line6',
delay=(5.94e-3, 5.6e-3), open_state=1) #Delays measured and set 2026-FEB-26. See lab notebook for details.
DigitalOut(name='LCR_do', parent_device=NI6363, connection='port0/line7')
DigitalOut(name='scope_trig_do', parent_device=NI6363, connection='port0/line8')
DigitalOut(name='dummy_do', parent_device=NI6363, connection='port0/line9')
# Define analog outs on 6363. Using these as digital outs for now.
AnalogOut(name='LCR_HOR_ao', parent_device=NI6363, connection='ao0')
AnalogOut(name='LCR_TOP_ao', parent_device=NI6363, connection='ao1')
# Define analog outs on 6738
# Make sure to define an even number of channels for Labscript to be happy
AnalogOut(name='ao0', parent_device=NI6738, connection='ao0')
AnalogOut(name='ao1', parent_device=NI6738, connection='ao1')
AnalogOut(name='ao2', parent_device=NI6738, connection='ao2')
AnalogOut(name='MAIN_JUMP_AMP_ao', parent_device=NI6738, connection='ao3')
AnalogOut(name='REPUMP_JUMP_AMP_ao', parent_device=NI6738, connection='ao4')
AnalogOut(name='ao5', parent_device=NI6738, connection='ao5')
AnalogOut(name='ao6', parent_device=NI6738, connection='ao6')
AnalogOut(name='ao7', parent_device=NI6738, connection='ao7')
# Define analog ins on 6363
AnalogIn(name='ai0', parent_device=NI6363, connection='ai0')
AnalogIn(name='ai1', parent_device=NI6363, connection='ai1')
# Again, make sure to define an even number of channels for Labscript to be happy
#do0 = DigitalOut('do0', ao6738, 'port0/line1')
DigitalOut('do1_dummy', NI6738, 'port0/line0') # dummy to make even number of digital lines
cam = IDS_PeakCamera(
name='my_ids_camera',
parent_device=NI6738,
connection='port0/line1',
serial_number='4108596607', #sn yellow 4103389953 blue 4108596607 red 4108596608
minimum_recovery_time=0.005, # Override the default
trigger_edge_type='rising', # We will trigger via software
trigger_duration=0.05,
camera_attributes={
'trigger': 'On', # On/Off
'format': 'Mono8', # Mono8/Mono12
'exposure': 1, # 9 ms, using the wrapper property
'fps': 5.0, # required by base class (will be skipped at runtime)
'gain': 0.0
},
manual_mode_camera_attributes={ # BLACS preview mode
"trigger": "Off",
"format": "Mono8",
"exposure": 2.5,
"fps": 5.0, # shown in BLACS, not applied to hardware
"gain": 1.0,
},
)
bbd = BBD301(
name='bbd301',
parent_device=prawn.clocklines[0],
serial_number='103512594', # your actual serial number
num_channels=1,
)
if __name__ == '__main__':
ct()
start()
stop(0.001)