[i]
Start row DN = 3
bin DN = 20
Start row UP = 116
bin UP = 40
Start row dc = 41
bin dc = 30
side choice = 2
Start row DN 2 = 129
Start row UP 2 = 379
Start row dc 2 = 259
bin DN 2 = 8
bin UP 2 = 8
bin dc 2 = 8
side choice 2 = 2
bin dc 2 b = 30
Start row dc b = 41
bin dc b = 30
Start row dc b 2 = 259
bin dc b 2 = 8
[d]
Exposure time (sec) = 0.030000
Temperature Up = 2645.000000
Temperature Dn = 2645.000000
Start Wavelength (nm) = 600.000000
End Wavelength (nm) = 800.000000
threshold = 100.000000
scalar background = 0.000000
Temperature Dn 2 = 2644.000000
Temperature Up 2 = 2644.000000
Start Wavelength (nm) 2 = 600.000000
End Wavelength (nm) 2 = 800.000000
threshold 2 = 150.000000
scalar background 2 = 992.000000
R1_0 = 694.500000
R1_0_up = 695.580000
R1_0_dn = 694.260000
up offset = 1.370000
dn offset = 0.050000
R1 @ 0GPa = 694.210000
Start Wavelength (nm) 3 = 675.000000
End Wavelength (nm) 3 = 760.000000
[s]
trigger pv = "16idb:us_las_trig.VAL"
Upstream temperature pv = "16idb:us_las_temp.VAL"
Downstream temperatue pv = "16idb:ds_las_temp.VAL"
Detector saturation warning pv = "16idb:thermalWarning"
Temperature file name pv = "16idb:Temperature_FileName.VAL"
Exposure time pv = "16idb:ccd_exposure_time.VAL"
PIXIS exp name = "PIXIS Setup1"
PI-MAX 4 exp name = "PIXIS Setup1"
file name convention = "T %d.SPE"
file name formatting = "T %d.SPE"
[b]
EPICS ON = FALSE
use scalar background = FALSE
Full range? = FALSE
x pixel binning = TRUE
Detector selection = TRUE
Aquisition software = FALSE
use scalar background 2 = TRUE
x pixel binning 2 = TRUE
Full range? 2 = TRUE
WL correct = FALSE
EPICS out ON = FALSE
[p]
Downstream side calibration file = "/C/Users/Ross/Desktop/2019 June 12-6.5A-2993K-50um-no pinhole-nist.spe"
Upstream side calibration file = "/C/Users/Ross/Desktop/2019 June 12-6.5A-2993K-50um-no pinhole-nist.spe"
Downstream side calibration file 2 = "/C/Users/hrubiak/Desktop/Ex089/temperature/Dec21_2015/UP Gain1.spe"
Upstream side calibration file 2 = "/C/Users/hrubiak/Desktop/Ex089/temperature/Dec21_2015/DN Gain1.spe"
Upstream side calibration file 3 = "/C/Users/Ross/Documents/T 37.OO_Spec"
Downstream side calibration file 3 = "/C/Users/Ross/Documents/T 37.OO_Spec"