Notifications
You must be signed in to change notification settings - Fork 531
Expand file tree
/
Copy pathinit.lua
More file actions
162 lines (136 loc) · 6.26 KB
/
init.lua
File metadata and controls
162 lines (136 loc) · 6.26 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
-- Copyright 2025 SmartThings, Inc.
-- Licensed under the Apache License, Version 2.0
local capabilities = require "st.capabilities"
local clusters = require "st.zigbee.zcl.clusters"
local constants = require "st.zigbee.constants"
local log = require "log"
local configurationMap = require("configurations")
local SimpleMetering = clusters.SimpleMetering
local ElectricalMeasurement = clusters.ElectricalMeasurement
local Alarms = clusters.Alarms
local VOLTAGE_MEASUREMENT_MULTIPLIER_KEY = "_voltage_measurement_multiplier"
local VOLTAGE_MEASUREMENT_DIVISOR_KEY = "_voltage_measurement_divisor"
local CURRENT_MEASUREMENT_MULTIPLIER_KEY = "_current_measurement_multiplier"
local CURRENT_MEASUREMENT_DIVISOR_KEY = "_current_measurement_divisor"
local POWER_FAILURE_ALARM_CODE = 0x03
local function alarm_report_handler(driver, device, zb_rx)
local alarm_status = zb_rx.body.zcl_body
if ((alarm_status.cluster_identifier.value == SimpleMetering.ID) and (alarm_status.alarm_code.value == POWER_FAILURE_ALARM_CODE)) then
device.thread:call_with_delay(2, function(d)
device:emit_event_for_endpoint(zb_rx.address_header.src_endpoint.value, capabilities.powerSource.powerSource.unknown())
end
)
end
end
local function device_added(driver, device)
end
-- Handler for voltage measurement
local function voltage_measurement_handler(driver, device, value, zb_rx)
local raw_value = value.value
-- By default emit raw value
local multiplier = device:get_field(VOLTAGE_MEASUREMENT_MULTIPLIER_KEY) or 1
local divisor = device:get_field(VOLTAGE_MEASUREMENT_DIVISOR_KEY) or 1
raw_value = raw_value * multiplier / divisor
local mult = 10 ^ 1 -- Round off to 1 decimal place
raw_value = math.floor(raw_value * mult + 0.5) / mult
if device:supports_capability(capabilities.voltageMeasurement) then
device:emit_event_for_endpoint(zb_rx.address_header.src_endpoint.value, capabilities.voltageMeasurement.voltage({ value = raw_value, unit = "V" }))
end
if device:supports_capability(capabilities.powerSource) then
device:emit_event(capabilities.powerSource.powerSource.mains())
end
end
local function current_measurement_divisor_handler(driver, device, divisor, zb_rx)
local raw_value = divisor.value
if raw_value == 0 then
log.warn("Current scale divisor is 0; using 1 to avoid division by zero")
raw_value = 1
end
device:set_field(CURRENT_MEASUREMENT_DIVISOR_KEY, raw_value, { persist = true })
end
local function current_measurement_multiplier_handler(driver, device, multiplier, zb_rx)
local raw_value = multiplier.value
device:set_field(CURRENT_MEASUREMENT_MULTIPLIER_KEY, raw_value, { persist = true })
end
local function voltage_measurement_divisor_handler(driver, device, divisor, zb_rx)
local raw_value = divisor.value
if raw_value == 0 then
log.warn("Voltage scale divisor is 0; using 1 to avoid division by zero")
raw_value = 1
end
device:set_field(VOLTAGE_MEASUREMENT_DIVISOR_KEY, raw_value, { persist = true })
end
local function voltage_measurement_multiplier_handler(driver, device, multiplier, zb_rx)
local raw_value = multiplier.value
device:set_field(VOLTAGE_MEASUREMENT_MULTIPLIER_KEY, raw_value, { persist = true })
end
-- Handler for current measurement
local function current_measurement_handler(driver, device, value, zb_rx)
local raw_value = value.value
-- By default emit raw value
local multiplier = device:get_field(CURRENT_MEASUREMENT_MULTIPLIER_KEY) or 1
local divisor = device:get_field(CURRENT_MEASUREMENT_DIVISOR_KEY) or 1
raw_value = raw_value * multiplier / divisor
local mult = 10 ^ 2 -- Round off to 2 decimal places
raw_value = math.floor(raw_value * mult + 0.5) / mult
if device:supports_capability(capabilities.currentMeasurement) then
device:emit_event_for_endpoint(zb_rx.address_header.src_endpoint.value, capabilities.currentMeasurement.current({ value = raw_value, unit = "A" }))
end
end
-- Device init function
local function device_init(driver, device)
device:set_field(constants.SIMPLE_METERING_DIVISOR_KEY, 1000, {persist = true})
device:set_field(constants.ELECTRICAL_MEASUREMENT_DIVISOR_KEY, 1000, {persist = true})
-- Indicate device is powered by mains
if device:supports_capability(capabilities.powerSource) then
device:emit_event(capabilities.powerSource.powerSource.mains())
end
end
local function do_configure(driver, device)
local configuration = configurationMap.get_device_configuration(device)
if configuration ~= nil then
for _, attribute in ipairs(configuration) do
device:add_configured_attribute(attribute)
end
end
device:configure()
local alarms_endpoint = device:get_endpoint(Alarms.ID) or device.fingerprinted_endpoint_id
-- Make sure we have a valid endpoint number before sending the bind request
if alarms_endpoint ~= nil then
device:send(ElectricalMeasurement.attributes.ACVoltageMultiplier:read(device))
device:send(ElectricalMeasurement.attributes.ACVoltageDivisor:read(device))
device:send(ElectricalMeasurement.attributes.ACCurrentMultiplier:read(device))
device:send(ElectricalMeasurement.attributes.ACCurrentDivisor:read(device))
else
log.warn("No valid endpoint found for Alarms cluster binding")
end
device:refresh()
end
-- Main driver definition
local frient_smart_plug = {
NAME = "frient Smart Plug",
zigbee_handlers = {
cluster = {
[Alarms.ID] = {
[Alarms.client.commands.Alarm.ID] = alarm_report_handler
}
},
attr = {
[ElectricalMeasurement.ID] = {
[ElectricalMeasurement.attributes.ACVoltageMultiplier.ID] = voltage_measurement_multiplier_handler,
[ElectricalMeasurement.attributes.ACVoltageDivisor.ID] = voltage_measurement_divisor_handler,
[ElectricalMeasurement.attributes.RMSVoltage.ID] = voltage_measurement_handler,
[ElectricalMeasurement.attributes.ACCurrentMultiplier.ID] = current_measurement_multiplier_handler,
[ElectricalMeasurement.attributes.ACCurrentDivisor.ID] = current_measurement_divisor_handler,
[ElectricalMeasurement.attributes.RMSCurrent.ID] = current_measurement_handler
}
},
},
lifecycle_handlers = {
init = configurationMap.reconfig_wrapper(device_init),
doConfigure = do_configure,
added = device_added,
},
can_handle = require("frient.can_handle"),
}
return frient_smart_plug