Please confirm these before moving forward
UniGetUI Version
2026.1.9
Windows version, edition, and architecture
Windows 10 22H2 x64
Describe your issue
After updating to the latest version of UniGetUI, WinGet stopped working completely. I've tried resting WinGet, using portable build of WinGet, forcing Pinget and checking aliases in the Windows settings app and nothing worked.
Steps to reproduce the issue
No response
UniGetUI Log
[12.05.2026 03:10:54] __ __ _ ______ __ __ ______
/ / / /___ (_) ____/__ / /_/ / / / _/
/ / / / __ \/ / / __/ _ \/ __/ / / // /
/ /_/ / / / / / /_/ / __/ /_/ /_/ // /
\____/_/ /_/_/\____/\___/\__/\____/___/
Welcome to UniGetUI Version 2026.1.9
[12.05.2026 03:10:54]
[12.05.2026 03:10:54] Build 107
[12.05.2026 03:10:54] Data directory C:\Users\PC\AppData\Local\UniGetUI
[12.05.2026 03:10:54] Encoding Code Page set to 852
[12.05.2026 03:10:54] Command cargo-binstall.exe was not found on the system
[12.05.2026 03:10:54] PowerShell is not enabled
[12.05.2026 03:10:54] Cargo is not enabled
[12.05.2026 03:10:54] .NET Tool is not enabled
[12.05.2026 03:10:54] PowerShell7 is not enabled
[12.05.2026 03:10:54] Pip is not enabled
[12.05.2026 03:10:54] vcpkg is not enabled
[12.05.2026 03:10:54] Npm is not enabled
[12.05.2026 03:10:54] Chocolatey is not enabled
[12.05.2026 03:10:54] Scoop is not enabled
[12.05.2026 03:10:54] Command pinget.exe was not found on the system
[12.05.2026 03:10:54] Packaged WinGet COM activation failed (Retrieving the COM class factory for component with CLSID {C53A4F16-787E-42A4-B304-29EFFB4BF597} failed due to the following error: 80070003 System nie może odnaleźć określonej ścieżki. (0x80070003).), attempting lower-trust activation...
[12.05.2026 03:10:54] Lower-trust WinGet COM activation failed (0x80070003: System nie może odnaleźć określonej ścieżki. (0x80070003)).
[12.05.2026 03:10:54] Cannot instantiate Native WinGet Helper due to error: WinGet COM activation failed for CLSID c53a4f16-787e-42a4-b304-29effb4bf597 (IID b375e3b9-f2e0-5c93-87a7-b67497f7e593, AllowLowerTrustRegistration=True): System nie może odnaleźć określonej ścieżki.
[12.05.2026 03:10:54] WindowsPackageManager.Interop.WinGetComActivationException (0x80070003): WinGet COM activation failed for CLSID c53a4f16-787e-42a4-b304-29effb4bf597 (IID b375e3b9-f2e0-5c93-87a7-b67497f7e593, AllowLowerTrustRegistration=True): System nie może odnaleźć określonej ścieżki.
at WindowsPackageManager.Interop.WindowsPackageManagerStandardFactory.CreateInstance[T](Guid clsid, Guid iid) in D:\a\UniGetUI\UniGetUI\src\WindowsPackageManager.Interop\WindowsPackageManager\WindowsPackageManagerStandardFactory.cs:line 66
at WindowsPackageManager.Interop.WindowsPackageManagerFactory.CreateInstance[T]() in D:\a\UniGetUI\UniGetUI\src\WindowsPackageManager.Interop\WindowsPackageManager\WindowsPackageManagerFactory.cs:line 61
at UniGetUI.PackageEngine.Managers.WingetManager.NativeWinGetHelper.TryInitializeLowerTrustFactory() in D:\a\UniGetUI\UniGetUI\src\UniGetUI.PackageEngine.Managers.WinGet\ClientHelpers\NativeWinGetHelper.cs:line 103
--- End of stack trace from previous location ---
at UniGetUI.PackageEngine.Managers.WingetManager.NativeWinGetHelper..ctor(WinGet manager, Func`2 systemCliHelperFactory, Boolean skipInitialization, Func`1 localPackagesProvider, IPingetPackageDetailsProvider pingetPackageDetailsProvider) in D:\a\UniGetUI\UniGetUI\src\UniGetUI.PackageEngine.Managers.WinGet\ClientHelpers\NativeWinGetHelper.cs:line 85
at UniGetUI.PackageEngine.Managers.WingetManager.WinGet._loadManagerExecutableFile(Boolean& found, String& path, String& callArguments) in D:\a\UniGetUI\UniGetUI\src\UniGetUI.PackageEngine.Managers.WinGet\WinGet.cs:line 360
[12.05.2026 03:10:54] WinGet will resort to using WinGetCliHelper()
[12.05.2026 03:10:54] Winget is enabled and was found on C:\Users\PC\AppData\Local\Microsoft\WindowsApps\winget.exe
[12.05.2026 03:10:54] An error occurred while initialising package manager Winget
[12.05.2026 03:10:54] System.ComponentModel.Win32Exception (3): An error occurred trying to start process 'C:\Users\PC\AppData\Local\Microsoft\WindowsApps\winget.exe' with working directory 'C:\Program Files\UniGetUI'. System nie może odnaleźć określonej ścieżki.
at System.Diagnostics.Process.StartWithCreateProcess(ProcessStartInfo startInfo)
at UniGetUI.PackageEngine.Managers.WingetManager.WinGet._loadManagerVersion(String& version) in D:\a\UniGetUI\UniGetUI\src\UniGetUI.PackageEngine.Managers.WinGet\WinGet.cs:line 543
at UniGetUI.PackageEngine.ManagerClasses.Manager.PackageManager.Initialize() in D:\a\UniGetUI\UniGetUI\src\UniGetUI.PackageEngine.PackageManagerClasses\Manager\PackageManager.cs:line 102
[12.05.2026 03:10:54] Unable to retrieve secret for resource 'UniGetUI/GitHubAccessToken': Nie można odnaleźć elementu.
Nie można pobrać poświadczenia z magazynu
[12.05.2026 03:10:55] Downloaded new icons and screenshots successfully!
[12.05.2026 03:11:00] Integrity check passed successfully!
[12.05.2026 03:11:01] Command pinget.exe was not found on the system
Package Managers Logs
Manager WinGet with version:
——————————————————————————————————————————
Relevant information
Previously UniGetUI also had some problems with WinGet, but then it would fallback to it's own build and everything worked fine.
Screenshots and videos
No response
Please confirm these before moving forward
UniGetUI Version
2026.1.9
Windows version, edition, and architecture
Windows 10 22H2 x64
Describe your issue
After updating to the latest version of UniGetUI, WinGet stopped working completely. I've tried resting WinGet, using portable build of WinGet, forcing Pinget and checking aliases in the Windows settings app and nothing worked.
Steps to reproduce the issue
No response
UniGetUI Log
Package Managers Logs
Relevant information
Previously UniGetUI also had some problems with WinGet, but then it would fallback to it's own build and everything worked fine.
Screenshots and videos
No response